Device parameters

Configurable parameters
Parameter Allowed values Comments Default
Designation Item

Setpoint

000000 – 999999

from 000000 to 99999

000000
oUt

Output mode

1

Switched after setpoint. The output is triggered if the number of counted pulses is greater than setpoint value or equal to it.

1
2

Dispenser mode. The output is triggered if the number of counted pulses is in the range from zero to the setpoint value, and the last pulse that arrived at the “Start/Stop” input of the counter was the starting one.

FDP

Multiplier decimal point position

------ ------
-----.-
----.--
---.---
--.----
-.-----
F

Multiplier

0,00001 – 99999

from 0.00001 to 99999

1
DP

Decimal point position

------ ------
-----.-
----.--
---.---
--.----
SPM

Operation type after reaching setpoint

Cnt

Continue counting without resetting

rStCnt
rStCnt*

Reset counter and continue counting

rStStP

Reset counter and stop counting

The counter is waiting for the "Start" signal

rSt

Operation type to "Reset" signal

Cont*

Reset counter and continue counting

Cont
StoP

Reset counter and stop counting

The first impulse that came after the reset to the “Start/Stop” input will be considered as the starting one.

Notice
* These parameters are not available in the Dispenser mode (oUt = 2).
FREQ

Frequency of input filter

1 – 2500

Filtering signals at the counting input of the device (from 1 to 2500 Hz) - filter 1.

This parameter in the digital signal processing unit of the device is converted to the minimum pulse duration (tmin): t_{min} = {1\over2\cdot FrEq}

2500
Cnt.t

Minimum duration of the signal on the control inputs

200 – 999999

Filtering signals at the control inputs of the device (from 200 to 999999 μs) - filter 2

200
LoCK

Button lock

oFF

Buttons unlocked

oFF
1

Reset counter button locked

2

Reset and change of setpoints are blocked

dEFAUL

Restore factory settings

no

Do not restore settings

no
YES

Restore settings

PASS

Password

0000 – 9999

from 0000 to 9999

0000